Wood Designer forum
Problem with winders|Forum|WOOD DESIGNER
![Avatar](https://wooddesigner.org/wp-content/sp-resources/forum-avatars/defaults/moddefaultwd2.png)
January 20, 2017
![sp_UserOfflineSmall](https://wooddesigner.org/wp-content/sp-resources/forum-themes/reboot/images/lightpack/sp_UserOfflineSmall.png)
Hi,
please find your files attached
All the best, Alexandre
![Avatar](https://wooddesigner.org/wp-content/sp-resources/forum-avatars/defaults/moddefaultwd2.png)
August 7, 2014
![sp_UserOfflineSmall](https://wooddesigner.org/wp-content/sp-resources/forum-themes/reboot/images/lightpack/sp_UserOfflineSmall.png)
Hi Duayne,
I requested Alex to send you the documents today
regards
Michel
![Avatar](https://wooddesigner.org/wp-content/sp-resources/forum-avatars/defaults/moddefaultwd2.png)
August 7, 2014
![sp_UserOfflineSmall](https://wooddesigner.org/wp-content/sp-resources/forum-themes/reboot/images/lightpack/sp_UserOfflineSmall.png)
Hi Duayne
I will revert to you this evening as I am currently not available.
regards
Michel
![Avatar](https://wooddesigner.org/wp-content/sp-resources/forum-avatars/defaults/userdefault.png)
![](https://wooddesigner.org/wp-content/sp-resources/forum-badges/premium-support-new.png)
March 1, 2015
![sp_UserOfflineSmall](https://wooddesigner.org/wp-content/sp-resources/forum-themes/reboot/images/lightpack/sp_UserOfflineSmall.png)
I tried multiple ways to achieve this , in the end i did use 3 landings to make the 3 step winder ,
i was able to make a change in the length of the right side of the opening to 7′-5 13/16″ which gave me a run on each tread to 10″ i also dropped the number of treads to 9
this is working out better
![Avatar](https://wooddesigner.org/wp-content/sp-resources/forum-avatars/defaults/moddefaultwd2.png)
August 7, 2014
![sp_UserOfflineSmall](https://wooddesigner.org/wp-content/sp-resources/forum-themes/reboot/images/lightpack/sp_UserOfflineSmall.png)
Hi Duayne,
As stairdesigner is calculating in the European way we are not able to define the thread width as it gest calculated over the qty of steps and distance.
Also, the 3 steps winder is not a standard in this calculation. To achieve a 3 step winder the best way is to build up the flight with landing and edit the shape.
I have added a version that you can use to finish your project.
The only way to affect the tread width is to add or remove a step in the flight or change the length of the flight.
regards
Michel
![Avatar](https://wooddesigner.org/wp-content/sp-resources/forum-avatars/defaults/userdefault.png)
![](https://wooddesigner.org/wp-content/sp-resources/forum-badges/premium-support-new.png)
March 1, 2015
![sp_UserOfflineSmall](https://wooddesigner.org/wp-content/sp-resources/forum-themes/reboot/images/lightpack/sp_UserOfflineSmall.png)
I have a set of stairs that i am trying to make work to a specific length , Here in Canada we are only allowed 3 winders in a flight of stairs , if i make adjustments to the winders , it automatically changes the straight run per tread to over 11″ , i need to make the straight run with a tread width of 10″ ,
if i change the straight flight so the treads = 10″ it messes up the winders . the problem seems to be the winding coefficient , the controls for them don’t seem to have any effect on the outcome , the walking line here in Canada is 12″ from the handrails , i can’t find a way to make that happen
how can i make this work .
included is my file
1 Guest(s)
![sp_Information](https://wooddesigner.org/wp-content/sp-resources/forum-themes/reboot/images/lightpack/sp_Information.png)